Schneider Electric TeSys Island Direct Online Starter - TPRST080_x000D_ Forming part of Schneider Electrics TeSys Island range is this motor starter, predominantly used for direct starter connection to an automation controller through a bus coupler but is only operational when connected to the coupler. The functions that are available with this motor starter are upstream voltage presence detection, electrical line and load protection also power and energy monitoring when connected with the TPRVM voltage module._x000D_ Features & Benefits_x000D_ • This TeSys Island motor starter is compatible with the TPRBC bus coupler and the TPRVM voltage interface module_x000D_ • 3P (3 NO)_x000D_ • The utilisation category for this starter is AC-1, AC-2, AC-3 and AC-4_x000D_ • One to three phases_x000D_ • This device has a rated operational voltage of <= 690 V AC 47...63 Hz_x000D_ • Has the option to be reset remotely or automatically_x000D_ • Overvoltage category of III_x000D_ • The local signalling for this motor starter are 1 LED (green/red) DS (device status) and 1 LED (green/red) LS (load status)_x000D_ Motor Starter Protection Types_x000D_ • Motor overheat_x000D_ • Overcurrent_x000D_ • Undercurrent_x000D_ • Jam_x000D_ • Long start_x000D_ • Stall_x000D_ • Rapid cycle lockout_x000D_ • Phase sequence_x000D_ • Rapid restart lockout_x000D_ • Phase reversal_x000D_ • Phase loss_x000D_ • Phase unbalance_x000D_ • Ground current_x000D_ • Thermal overload protection_x000D_ Motor Starter Monitoring Types_x000D_ • Time device ON_x000D_ • Time device switch ON_x000D_ • Number of faults_x000D_ • Number of switching cycles_x000D_ • Number of device power cycles_x000D_ • Average current Iavg_x000D_ • Average voltage Vavg_x000D_ • Max current Imax_x000D_ • Max voltage Vmax_x000D_ • Active and reactive power with voltage module_x000D_ • Active and reactive energy with voltage module_x000D_ • True power factor with voltage module_x000D_ Discovering TeSys Island_x000D_ A concept that is dedicated to control and monitor machines and processes, each TeSys Island product plays an important role to switch, protect and manage motors and electrical loads up to 80 Amps (AC3) within an electrical control panel._x000D_ • A fantastic digital load management solution that enables your machines and processes to be smarter and reliable_x000D_ • TeSys Island provides a fully digitised and object-orientated load management system and is industry 4.0 compliant data provider_x000D_ • Through the use and installation of TeSys Island, users are able to reduce time to market and enable OEMs to move forward, faster in their industry 4.0 journey_x000D_ • Through the TeSys Island approach, users will be able to simplify the function of the applications and system configuration as well as reducing the number of engineering tasks_x000D_ • TeSys Island enables a faster machine engineering and installation phase_x000D_ • The TeSys Island concept can also be easily integrated into 3rd party automation systems, supporting several fieldbuses such as EtherNet/IP, Modbus TCP, PROFINET and PROFIBUS_x000D_ • Provides users access to all relevant load data for advanced system diagnostics_x000D_ A little more info..._x000D_ • Manages motors electrical loads of up to 80 A (AC-3)/37 kW/40 hp_x000D_ • Features fieldbus connectivity via bus coupler for EtherNet/IP, Modbus TCP, PROFINET or PROFIBUS_x000D_ • There are relevant load data available, such as current, power, energy and advanced diagnostic data_x000D_ • The TeSys Island avatar objects and dedicated configuration and maintenance tools provide simplified engineering and commissioning_x000D_ • Users can have up to 20 modules on 1 island mounted on DIN rail (up to 112 cm length)_x000D_ • Thanks to the fill connectivity over fieldbus, no control or auxiliary wiring are required_x000D_ • There is no need for mechanical dials or dip switches due to all the adjustments and settings being digitised_x000D_ • A limited number of references including 5 starter sizes, digital & analog I/Os and voltage measurement modules_x000D_ • Embedded Cybersecurity (Achilles Level 2)_x000D_ • There is a SIL starter available, designed for the integration into functional safety systems which are according to IEC 61508, IEC 62061 and ISO 13849-1, including TUV certification (Stop 0 and 1 with wiring categories 1 to 2, suitable for PL c, d and SIL level 2_x000D_ • Fully complaint to international standards (IEC / UL / CSA 61010, IEC / UL / CSA 60947, GB/T14018)_x000D_ • Please refer to the technical references for more information_x000D_ Configure with the TeSys Island Configurator tool building a complete solution. Use the link listed to go to the Configurator Tool._x000D_ https://uk.rs-online.com/web/generalDisplay.html?id=schneider-smart-industry&intcmp=UK-WEB-_-BP-MFP-_-DTC__1119_NE-_-schneider
Наш менеджер свяжется с вами в ближайшее время