Schneider Electric TeSys Island Direct Online SIL Starter - TPRSS025_x000D_
Forming part of Schneider Electrics TeSys Island range is this SIL motor starter which is used for a direct starter connection to an automation controller through a bus coupler but is only operational when connected to the coupler. The functions that are available with this motor starter are upstream voltage presence detection, electrical line and load protection, power and energy monitoring when connected with the TPRVM voltage module and a safe stop function is available when connected to the TPRSM module._x000D_
Features & Benefits_x000D_
This TeSys Island motor starter is compatible with the TPRBC bus coupler, the TPRVM voltage interface module and the TPRSM SIL interface module_x000D_
3P (3 NO)_x000D_
The utilisation category for this starter is AC-1, AC-2, AC-3 and AC-4_x000D_
One to three phases_x000D_
This device has a rated operational voltage of <= 480 V AC 47...63 Hz for overvoltage cat. III and <= 690 V AC 47...63 Hz for overvoltage cat. II_x000D_
The rated operational current is 25 A (at <50 °C) at <= 440 V AC-3 and 30 A (at <50 °C) at <= 440 V AC-1_x000D_
Has the option to be reset remotely or automatically_x000D_
The local signalling for this motor starter is 1 LED (green/red) DS (device status) and 1 LED (green/red) LS (load status)_x000D_
Features a thermal protection adjustment range of 0.5 to 25 A_x000D_
Motor Starter Protection Types_x000D_
Thermal overload protection_x000D_
Motor overheat_x000D_
Overcurrent_x000D_
Undercurrent_x000D_
Jam_x000D_
Long start_x000D_
Stall_x000D_
Rapid cycle lockout_x000D_
Rapid restart lockout_x000D_
Phase sequence_x000D_
Phase loss_x000D_
Phase reversal_x000D_
Phase unbalance_x000D_
Ground current_x000D_
Motor Starter Monitoring Types_x000D_
Time device ON_x000D_
Time device switch ON_x000D_
Number of faults_x000D_
Number of switching cycles_x000D_
Number of device power cycles_x000D_
Average current Iavg_x000D_
Average voltage Vavg_x000D_
Max current Imax_x000D_
Max voltage Vmax_x000D_
Active and reactive power with voltage module_x000D_
Active and reactive energy with voltage module_x000D_
True power factor with voltage module_x000D_
Discovering TeSys Island_x000D_
A concept that is dedicated to control and monitor machines and processes, each TeSys Island product plays an important role to switch, protect and manage motors and electrical loads up to 80 Amps (AC3) within an electrical control panel._x000D_
A fantastic digital load management solution that enables your machines and processes to be smarter and reliable_x000D_
TeSys Island provides a fully digitised and object-orientated load management system and is industry 4.0 compliant data provider_x000D_
Through the use and installation of TeSys Island, users are able to reduce time to market and enable OEMs to move forward, faster in their industry 4.0 journey_x000D_
Through the TeSys Island approach, users will be able to simplify the function of the applications and system configuration as well as reducing the number of engineering tasks_x000D_
TeSys Island enables a faster machine engineering and installation phase_x000D_
The TeSys Island concept can also be easily integrated into 3rd party automation systems, supporting several fieldbuses such as EtherNet/IP, Modbus TCP, PROFINET and PROFIBUS_x000D_
Provides users access to all relevant load data for advanced system diagnostics_x000D_
A little more info..._x000D_
Manages motors electrical loads of up to 80 A (AC-3)/37 kW/40 hp_x000D_
Features fieldbus connectivity via bus coupler for EtherNet/IP, Modbus TCP, PROFINET or PROFIBUS_x000D_
There are relevant load data available, such as current, power, energy and advanced diagnostic data_x000D_
The TeSys Island avatar objects and dedicated configuration and maintenance tools provide simplified engineering and commissioning_x000D_
Users can have up to 20 modules on 1 island mounted on DIN rail (up to 112 cm length)_x000D_
Thanks to the fill connectivity over fieldbus, no control or auxiliary wiring are required_x000D_
There is no need for mechanical dials or dip switches due to all the adjustments and settings being digitised_x000D_
A limited number of references including 5 starter sizes, digital & analog I/Os and voltage measurement modules_x000D_
Embedded Cybersecurity (Achilles Level 2)_x000D_
There is a SIL starter available, designed for the integration into functional safety systems which are according to IEC 61508, IEC 62061 and ISO 13849-1, including TUV certification (Stop 0 and 1 with wiring categories 1 to 2, suitable for PL c, d and SIL level 2_x000D_
Fully complaint to international standards (IEC / UL / CSA 61010, IEC / UL / CSA 60947, GB/T14018)_x000D_
Please refer to the technical references for more information_x000D_
Configure with the TeSys Island Configurator tool building a complete solution. Use the link listed to go to the Configurator Tool._x000D_
https://uk.rs-online.com/web/generalDisplay.html?id=schneider-smart-industry&intcmp=UK-WEB-_-BP-MFP-_-DTC__1119_NE-_-schneider
Наш менеджер свяжется с вами в ближайшее время