Работаем с юридическими лицами, бюджетными организациями, ИП
По вопросам приобретения товара пишите на info@west-cs.ru
Оплата по безналичному расчету согласно выставленному счету
Самовывоз - бесплатно, от 300руб. до пункта выдачи в Вашем городе, доставка от 500руб. "до двери"
Schneider Electric Modicon M262 Logic Controller_x000D_ Forming part of the Modicon M262 range of products is this 8 axes logic motion controller operates at a rated voltage of 24V DC. It has short-circuit and overload protection with automatic reset, reverse polarity protection and a manual short circuit protection._x000D_ • The communication port protocols are Ethernet IP/Modbus TCP, Sercos III, Serial link, Modbus RTU and ASCII, HTTP and HTTPS_x000D_ • 7 remote and 7 local I/O expansion modules_x000D_ • With a real time clock_x000D_ • LED signalling_x000D_ • Dimensions: H100mm x D90mm x W125mm_x000D_ • Reset time: 200ms automatic reset fast output_x000D_ • Memory capacity: 32MB for program RAM, 32MB for OS/website RAM, 192MB for system memory RAM_x000D_ • Maximum leakage current: 10 μA for output_x000D_ Range Information - Modicon M262_x000D_ The M262 Logic/Motion Controller is a control system that offers an all-in-one solution for motion applications and a scalable solution for logic applications, with optimised configurations and an open, expandable architecture. The M262 Logic/Motion Controller has various powerful features and can service a wide range of applications. Software configuration, programming, and commissioning are accomplished with the EcoStruxure Machine Expert software version 1.1. Maximum hardware configuration can be achieved as well as local and remote configurations._x000D_ Programming Languages - The M262 Logic/Motion Controller is configured and programmed with the EcoStruxure Machine Expert software, which supports the following IEC 61131-3 programming languages:_x000D_ • IL: Instruction List_x000D_ • ST: Structured Text_x000D_ • FBD: Function Block Diagram_x000D_ • SFC: Sequential Function Chart_x000D_ • LD: Ladder Diagram_x000D_ EcoStruxure Machine Expert software can also be used to program these controllers using CFC (Continuous Function Chart) language._x000D_ Power Supply - The power supply of the M262 Logic/Motion Controller is 24 Vdc_x000D_ Real-Time Clock - The M262 Logic/Motion Controller includes a Real-Time Clock (RTC) system. The system time is maintained by capacitors when the power is off. The time is maintained for 1 000 hours when the controller is not supplied._x000D_ Run/Stop - The M262 Logic/Motion Controller can be operated externally by the following:_x000D_ • A hardware Run/Stop switch_x000D_ • A Run/Stop operation by a dedicated digital input, defined in the software configuration. For more information, refer to Configuration of Digital Inputs (see Modicon M262 Logic/Motion Controller, Programming Guide)._x000D_ • An EcoStruxure Machine Expert software command_x000D_ • The system variable PLC_W in a Relocation Table_x000D_ • The Web server_x000D_ Memory - Three different memory types - RAM, Flash and Non-volatile RAM which suits a variant of uses and comes in different sizes_x000D_ Embedded Inputs/Output types - Fast inputs and fast source outputs_x000D_ Encoder - Incremental and SSI encoder modes available_x000D_ Removable Storage - The M262 Logic/Motion Controllers include an integrated SD card slot. The main uses of the SD card are:_x000D_ • Initializing the controller with a new application_x000D_ • Updating the controller and expansion module firmware_x000D_ • Applying post configuration files to the controller_x000D_ • Storing recipes, files_x000D_ • Receiving data logging files_x000D_ Embedded Communication Features - The Modicon M262 range features embedded communication features, it has Ethernet, USB Mini-B, Serial Line and Sercos communication ports available._x000D_ What is a PLC CPU?_x000D_ A PLC (programmable logic controller) is an industrial digital computer designed for the control of manufacturing processes or robotic devices where reliability control, simple programming and fault diagnosis is necessary. They were originally built to replace electromechanical relay systems in industrial automation._x000D_ A CPU (central processing unit) forms part of the PLC system. PLC CPUs are microprocessor-based and act as the electronic circuitry within an industrial computer. They carry out instructions from the computer program, performing basic mathematical, logical, control, input and output operations.
Наш менеджер свяжется с вами в ближайшее время