Работаем с юридическими лицами, бюджетными организациями, ИП
По вопросам приобретения товара пишите на info@west-cs.ru
TeSys LE Enclosed DOL Motor Starter._x000D_
From Schneider Electric this is the TeSys LE series of enclosed D.O.L motor starters and soft starters (direct-on-line and star-delta starters) with up to 37 kW for motors up to 80 A (400 V). The TeSys LE range are compact motor starters, can be installed for local control and wall mounted quick and easy to use and simple to install plus are available in various solutions._x000D_
Features and Benefits._x000D_
TeSys LE enclosed motor starters._x000D_
Pre-wired circuit._x000D_
Easy access cable entry._x000D_
IP 65 Protection excellent for harsh environments._x000D_
Can be DIN rail mounted._x000D_
Push button control._x000D_
Simple to install – excellent for speedy installation._x000D_
Cable entry._x000D_
Continuous service due to coordination._x000D_
D.O.L Starters._x000D_
LE1, LE2 range: contactor + overload Relay Up to 37 KW._x000D_
Available in Reversing and Non-reversing starters_x000D_
Conforms to standards IEC 60947-4-1_x000D_
IP 65 degree of protection._x000D_
Ambient air temperature: operation from -5°C to +40 °C._x000D_
For supply voltages between 380 and 440 V the Control circuit is pre-wired between phases. For other supply voltages the control circuit must be wired by the customer._x000D_
Overload relay must be ordered separately except LE1M pre-configured range._x000D_
Operating positions are the same as contactors._x000D_
Enclosure is made from - LE2 K and LE D09-D35 in Polycarbonate, LE D40A-D65A in Sheet Steel._x000D_
D.O.L. Starters with a fuse disconnecting switch._x000D_
Direct on-line LE4, LE8 range fuse switch-disconnector + contactor + overload relay Up to 15 kW._x000D_
Available in Reversing and Non-reversing starters._x000D_
Conforms to standards IEC 60947-4-1._x000D_
IP 65 degree of protection._x000D_
Ambient air temperature: Operation from -5 to +40 C._x000D_
For supply voltages between 380 and 440 V the Control circuit is pre-wired between phases. For other supply voltages, the control circuit must be wired by the customer._x000D_
Overload relay must be ordered separately, same as for fuse._x000D_
Enclosure is made from Polycarbonate._x000D_
D.O.L Starters enclosure for thermal magnetic circuit breaker and contactor._x000D_
LE1GV Enclosure for thermal magnetic circuit breaker + contactor Up to 5.5 kW._x000D_
Conforms to standards IEC 60947-4-1._x000D_
IP 55 degree of protection._x000D_
Enclosure is made from Polycarbonate_x000D_
Star-delta starters._x000D_
Star-delta LE3 range contactors + overload relay Up to 30 kW._x000D_
Conforms to standards IEC 60947-4-1._x000D_
IP 65 degree of protection._x000D_
For supply voltages between 380 and 415 V the Control circuit is pre-wired between phases. For other supply voltages, the control circuit must be wired by the customer._x000D_
Overload relay must be ordered separately._x000D_
Enclosure is made from Polycarbonate._x000D_
Applications._x000D_
All types of industry._x000D_
Infrastructure._x000D_
Buildings._x000D_
Machines that need (D.O.L Motor starting or motor stopping, Reverse and Non-reverse starting, Simple soft starting._x000D_
Overload protection with or without an isolating device._x000D_
Note_x000D_
Please refer to the datasheet to confirm which model is supplied with or without relay._x000D_
Range Info - Plastic/Metal Combination Housings_x000D_
These motor starters are available in a selection of formats. All have removable steel base plates for rigidity when mounting to an uneven surface and ease of earthing and wiring and an impact resistant polycarbonate front cover which is adaptable to enable the fitting of other components without drilling. Switching category is AC3 and the enclosures are IP65 rated.
Наш менеджер свяжется с вами в ближайшее время