Работаем с юридическими лицами, бюджетными организациями, ИП
По вопросам приобретения товара пишите на info@west-cs.ru
Оплата по безналичному расчету согласно выставленному счету
Самовывоз - бесплатно, от 300руб. до пункта выдачи в Вашем городе, доставка от 500руб. "до двери"
Schneider Electric LC1D TeSys D Contactors._x000D_ TeSys D Contactors from Schneider Electric combine long mechanical and electrical life to offer a high reliable contactor. The range has been designed for integration in control systems and can be used to create motor starters for any type of application. The TeSys D contactors offer quick simple setup while maintaining compliance with international standards._x000D_ Features and Benefits._x000D_ Built-in auxiliary contacts for added switching capability_x000D_ Screw connections: IP20 finger-safe terminals with both North American and International terminal markings_x000D_ Can be panel mounted with screws or DIN Rail mounted_x000D_ Bidirectional peak limiting diode suppressor to protect the coil_x000D_ Easily installed accessories_x000D_ Flexible control circuit to suit a wide range of applications_x000D_ What does the utilisation category AC1 and AC3 mean for the TeSys contactors?_x000D_ Contactor utilisation categories define the current making and breaking values, based on the type of load to be controlled and the operating cycle conditions._x000D_ AC-1: This applies to all AC devices with a power factor of at least 0.95. Example of use: resistive load, heating, distribution._x000D_ AC-3: This applies to squirrel cage motors where breaking occurs while the motor is running. Example of use: all squirrel cage motors, lifts, escalators, conveyors, bucket elevators, compressors, pumps, mixers, air conditioning units._x000D_ What accessories are available?_x000D_ Auxiliary contact blocks with serrated wiping action_x000D_ Front mount dust tight auxiliary contact blocks_x000D_ Pneumatic time delay blocks_x000D_ Transient voltage surge suppressors_x000D_ Interface modules and electronic timers_x000D_ Mechanical latching blocks_x000D_ Is the TeSys D range a double break pole type contactor?_x000D_ Yes, the Tesys D range uses linear translation movement that provides double breaking of the poles._x000D_ LC1D38FL Schneider Electric LC1D TeSys D Contactor Features._x000D_ Motor control and resistive load applications._x000D_ AC-1, AC-3 category._x000D_ = 690 V AC 25...400 Hz for power circuit, <= 300 V DC for power circuit Ue rated voltage._x000D_ 38 A (<= 60 °C) at <= 440 V AC AC-3 for power circuit, 50 A (<= 60 °C) at <= 440 V AC AC-1 for power circuit Ie rated current._x000D_ 18.5 kW at 380...400 V AC 50/60 Hz, 18.5 kW at 500 V AC 50/60 Hz, 18.5 kW at 660...690 V AC 50/60 Hz, 18.5 kW at 415...440 V AC 50/60 Hz, 9 kW at 220...230 V AC 50/60 Hz, Kw motor power._x000D_ DC Low consumption circuit._x000D_ 110 V dc Circuit voltage._x000D_ 1 NO + 1NC auxiliary contact._x000D_ Overvoltage category III._x000D_ Rated breaking capacity 550 A at 440 V for power circuit conforming to IEC 60947._x000D_ Complete with a protective cover._x000D_ Plate and Rail mounting._x000D_ IP2x front face conforming to IEC 60529_x000D_ Standards_x000D_ EN 60947-4-1, EN 60947-5-1, IEC 60947-4-1, IEC 60947-5-1, UL 508, CSA C22.2 No 14_x000D_ Certificate No._x000D_ BV, CCC, CSA, DNV, G,L GOS,T RINA, UL, LROS
Наш менеджер свяжется с вами в ближайшее время