Schneider Electric LC1D TeSys D Contactors._x000D_ TeSys D Contactors from Schneider Electric combine long mechanical and electrical life to offer a high reliable contactor. The range has been designed for integration in control systems and can be used to create motor starters for any type of application. The TeSys D contactors offer quick simple setup while maintaining compliance with international standards._x000D_ Features and Benefits._x000D_ Built-in auxiliary contacts for added switching capability._x000D_ Screw connections: IP20 finger-safe terminals with both North American and International terminal markings._x000D_ Can be panel mounted with screws or DIN Rail mounted._x000D_ Bidirectional peak limiting diode suppressor to protect the coil._x000D_ Easily installed accessories._x000D_ Flexible control circuit to suit a wide range of applications._x000D_ What does the utilisation category AC1 and AC3 mean for the TeSys contactors?_x000D_ Contactor utilisation categories define the current making and breaking values, based on the type of load to be controlled and the operating cycle conditions._x000D_ AC-1: This applies to all AC devices with a power factor of at least 0.95. Example of use: resistive load, heating, distribution._x000D_ AC-3: This applies to squirrel cage motors where breaking occurs while the motor is running. Example of use: all squirrel cage motors, lifts, escalators, conveyors, bucket elevators, compressors, pumps, mixers, air conditioning units._x000D_ What accessories are available?_x000D_ Auxiliary contact blocks with serrated wiping action._x000D_ Front mount dust tight auxiliary contact blocks._x000D_ Pneumatic time delay blocks._x000D_ Transient voltage surge suppressors._x000D_ Interface modules and electronic timers._x000D_ Mechanical latching blocks._x000D_ Is the TeSys D range a double break pole type contactor?_x000D_ Yes, the Tesys D range uses linear translation movement that provides double breaking of the poles._x000D_ LC1D18K7 Schneider Electric LC1D TeSys D Contactor Features._x000D_ Motor Control and Resistive load applications._x000D_ AC-1, AC-3, category._x000D_ Ue Rated voltage <= 690 V AC 25...400 Hz for power circuit, <= 300 V DC for power circuit._x000D_ Rated current 18 A (<= 60 °C) at <= 440 V AC AC-3 for power circuit, 32 A (<= 60 °C) at <= 440 V AC AC-1 for power circuit._x000D_ 100 V AC 50/60 Hz Control circuit voltage._x000D_ 1 NO + 1 NC auxiliary contact._x000D_ Overvoltage category III._x000D_ Rated breaking capacity 300 A at 440 V for power circuit conforming to IEC 60947._x000D_ Complete with a protective cover._x000D_ Plate and Rail mounting._x000D_ IP2x front face conforming to IEC 60529._x000D_ Approvals_x000D_ BV, CCC, CSA, DNV, GL, GOST, RINA, UL, LROS._x000D_ Standards_x000D_ EN 60947-4-1, EN 60947-5-1, IEC 60947-4-1, IEC 60947-5-1, UL 508, CSA C22.2 No 14.
Наш менеджер свяжется с вами в ближайшее время