Работаем с юридическими лицами, бюджетными организациями, ИП
По вопросам приобретения товара пишите на info@west-cs.ru
Оплата по безналичному расчету согласно выставленному счету
Самовывоз - бесплатно, от 300руб. до пункта выдачи в Вашем городе, доставка от 500руб. "до двери"
Schneider Electric LC1D TeSys D Contactors_x000D_ TeSys D Contactors from Schneider Electric combine long mechanical and electrical life to offer a high reliable contactor. The range has been designed for integration in control systems and can be used to create motor starters for any type of application. The TeSys D contactors offer quick simple setup while maintaining compliance with international standards._x000D_ Features and Benefits_x000D_ • Built-in auxiliary contacts for added switching capability_x000D_ • Screw connections: IP20 finger-safe terminals with both North American and International terminal markings_x000D_ • Can be panel mounted with screws or DIN Rail mounted_x000D_ • Bidirectional peak limiting diode suppressor to protect the coil_x000D_ • Easily installed accessories_x000D_ • Flexible control circuit to suit a wide range of applications_x000D_ What does the utilisation category AC1 and AC3 mean for the TeSys contactors?_x000D_ Contactor utilisation categories define the current making and breaking values, based on the type of load to be controlled and the operating cycle conditions._x000D_ AC-1: This applies to all AC devices with a power factor of at least 0.95. Example of use: resistive load, heating, distribution._x000D_ AC-3: This applies to squirrel cage motors where breaking occurs while the motor is running. Example of use: all squirrel cage motors, lifts, escalators, conveyors, bucket elevators, compressors, pumps, mixers, air conditioning units._x000D_ What accessories are available?_x000D_ • Auxiliary contact blocks with serrated wiping action_x000D_ • Front mount dust tight auxiliary contact blocks_x000D_ • Pneumatic time delay blocks_x000D_ • Transient voltage surge suppressors_x000D_ • Interface modules and electronic timers_x000D_ • Mechanical latching blocks_x000D_ Is the TeSys D range a double break pole type contactor?_x000D_ Yes the Tesys D range uses linear translation movement that provides double breaking of the poles._x000D_ LC1D12BL Schneider Electric LC1D TeSys D, TeSys Deca Contactor._x000D_ The Schneider Electric LC1D12BL model is a 3 pole contactor featuring a 24 V dc operating coil, with an AC-3 full load current rating of 12 A._x000D_ TeSys D, TeSys Deca._x000D_ Motor Control and Resistive load applications._x000D_ AC 4, AC-1, AC-3, AC-3e category._x000D_ Ue rated voltage Power circuit: <= 690 V AC 25...400 Hz, Power circuit: <= 300 V DC._x000D_ Rated current 25 A (at <= 440 V AC AC-1 for power circuit, 12 A (at <= 440 V AC AC-3 for power circuit, 12 A (at <= 440 V AC AC-3e for power circuit._x000D_ Circuit Voltage 24 V dc (DC low consumption circuit)._x000D_ 1 NO + 1 NC auxiliary contact._x000D_ Overvoltage category III._x000D_ Rated breaking capacity 250 A at 440 V for power circuit conforming to IEC 60947._x000D_ Complete with a protective cover._x000D_ Plate and Rail mounting._x000D_ IP20 front face conforming to IEC 60529._x000D_ Screw Clamp Terminals._x000D_ Built-in bidirectional peak limiting diode suppressor._x000D_ Weight 0.485 kg._x000D_ Fire resistant to 850 °C conforming to IEC 60695-2-1._x000D_ Approvals_x000D_ LROS (Lloyds register of shipping), CSA, UL, GOST, DNV, CCC, GL, BV, RINA, UKCA._x000D_ Standards_x000D_ CSA C22.2 No 14, EN 60947-4-1, EN 60947-5-1, IEC 60947-4-1, IEC 60947-5-1, UL 508, IEC 60335-1.
Наш менеджер свяжется с вами в ближайшее время