Schneider Electric LC1D TeSys D Contactors._x000D_
TeSys D Contactors from Schneider Electric combine long mechanical and electrical life to offer a high reliable contactor. The range has been designed for integration in control systems and can be used to create motor starters for any type of application. The TeSys D contactors offer quick simple setup while maintaining compliance with international standards._x000D_
Features and Benefits._x000D_
Built-in auxiliary contacts for added switching capability._x000D_
Screw connections: IP20 finger-safe terminals with both North American and International terminal markings._x000D_
Can be panel mounted with screws or DIN Rail mounted._x000D_
Bidirectional peak limiting diode suppressor to protect the coil._x000D_
Easily installed accessories._x000D_
Flexible control circuit to suit a wide range of applications._x000D_
What does the utilisation category AC1 and AC3 mean for the TeSys contactors?_x000D_
Contactor utilisation categories define the current making and breaking values, based on the type of load to be controlled and the operating cycle conditions._x000D_
AC-1: This applies to all AC devices with a power factor of at least 0.95. Example of use: resistive load, heating, distribution._x000D_
AC-3: This applies to squirrel cage motors where breaking occurs while the motor is running. Example of use: all squirrel cage motors, lifts, escalators, conveyors, bucket elevators, compressors, pumps, mixers, air conditioning units._x000D_
What accessories are available?_x000D_
Auxiliary contact blocks with serrated wiping action._x000D_
Front mount dust tight auxiliary contact blocks._x000D_
Pneumatic time delay blocks._x000D_
Transient voltage surge suppressors._x000D_
Interface modules and electronic timers._x000D_
Mechanical latching blocks._x000D_
Is the TeSys D range a double break pole type contactor?_x000D_
Yes, the Tesys D range uses linear translation movement that provides double breaking of the poles._x000D_
Schneider Electric LC1D096P7 Contactor_x000D_
The Schneider Electric LC1D096P7 model is a 3-pole contactor featuring a utilisation category of AC-1, AC-3 and AC-4. The control circuit voltage is 230 V AC 50/60 Hz with 1 NO + 1 NC auxiliary contact composition. The rated operation voltage is Power circuit: <= 690 V AC 25...400 Hz and Power circuit: <= 300 V DC._x000D_
Schneider Electric LC1D TeSys D Contactors_x000D_
TeSys D Contactors from Schneider Electric combine long mechanical and electrical life to offer a high reliable contactor. The range has been designed for integration in control systems and can be used to create motor starters for any type of application. The TeSys D contactors offer quick simple setup while maintaining compliance with international standards._x000D_
Features and Benefits_x000D_
Typically, applications include resistive loads and motor control_x000D_
Highly reliable_x000D_
Excellent quality_x000D_
TeSys D Green contactors keep the same high resistance to shock and vibration as TeSys D, their coils offer a wider control voltage band and a lower permanent consumption_x000D_
Built-in auxiliary contacts for added switching capability_x000D_
Screw connections: IP20 finger-safe terminals with both North American and International terminal markings_x000D_
Can be panel mounted with screws or DIN Rail mounted_x000D_
Bidirectional peak limiting diode suppressor to protect the coil_x000D_
Easily installed accessories_x000D_
Flexible control circuit to suit a wide range of applications_x000D_
What does the utilisation category AC1 and AC3 mean for the TeSys contactors?_x000D_
Contactor utilisation categories define the current making and breaking values, based on the type of load to be controlled and the operating cycle conditions._x000D_
AC-1: This applies to all AC devices with a power factor of at least 0.95. Example of use: resistive load, heating, distribution._x000D_
AC-3: This applies to squirrel cage motors where breaking occurs while the motor is running. Example of use: all squirrel cage motors, lifts, escalators, conveyors, bucket elevators, compressors, pumps, mixers, air conditioning units._x000D_
What accessories are available?_x000D_
Auxiliary contact blocks with serrated wiping action_x000D_
Front mount dust tight auxiliary contact blocks_x000D_
Pneumatic time delay blocks_x000D_
Transient voltage surge suppressors_x000D_
Interface modules and electronic timers_x000D_
Mechanical latching blocks_x000D_
Is the TeSys D range a double break pole type contactor?_x000D_
Yes, the TeSys D range uses linear translation movement that provides double breaking of the poles.