Altivar ATV212 Variable Frequency Drive (VFD)_x000D_
The Altivar ATV212 inverter drive is a recent updated version of the earlier version ATV21 variable speed motors from Schneider Electric. This VFD drive has an output frequency control of 0.5 to 200Hz, The Altivar 212 HVAC drive has been built for performance, intelligence and protection._x000D_
Features and Benefits_x000D_
Its important that the drive is mounted in a dust and damp proof enclosure whilst in certain environment such as dust, corrosive gases, and high humidity also around any dripping or splashing liquid. This is to protect the drive and to ensure that whilst in the enclosure the maximum internal temperature can reach 50 °C. To help encourage efficient circulation, we recommend that you fit ventilation grills and remove the blanking cover from the top of the drive. Please refer to the datasheet for more information regarding this._x000D_
The communication service allows the user to monitor inhibitable, read device identification, read holding registers, configure a time out setting, and write multiple registers and write a single register._x000D_
Features an integrated class C2 EMC filter._x000D_
The Altivar is a frequency controller for a three phase, squirrel cage motor._x000D_
Available as standard IP21 and IP55 protection_x000D_
Electrostatic discharge immunity test level 3, conforming to IEC 61000-4-2._x000D_
Less than 35% THDi harmonics due to Innovative C-less technology_x000D_
Embedded Building management communication protocols._x000D_
Incorporates 3 logic inputs, 2 analogue inputs, 2 logic outputs and one configurable analogue output._x000D_
Typical Applications_x000D_
Typically used in industrial and commercial applications, mainly focusing on ventilation due to the lack of airdraulic noise and motor noise._x000D_
Smoke extraction which has a forced start with fault inhibition._x000D_
Heating and Air conditioning, because of the optimised control in fluid processing and adjustable flow rates which improves energy management._x000D_
Pumping, useful in this application because of the multi-motor configuration and sleep/wake function. Alongside the detection of underload/over load._x000D_
When do the cooling fans on the ATV212 VFD switch on?_x000D_
The fan control strategy of the ATV212 means that the fans will start when the drive is in the RUN state. The fan will then stop after the STOP command has been given. There may be a time delay because of the thermal state._x000D_
Schneider Electric ATV212HD37N4 Variable Speed Inverter Drive AVT212._x000D_
Features._x000D_
Altivar 212 range._x000D_
Variable speed drive._x000D_
Short name – ATV212._x000D_
Destination - Asynchronous motors._x000D_
Specific application - Pumps and fans in HVAC._x000D_
With a Heat Sink._x000D_
3 (three) Phase network._x000D_
37 kW motor power (50 Hp)._x000D_
Rated supply voltage 380 – 480 V._x000D_
EMC Class C2 EMC filter integrated._x000D_
1 LED (red) for DC bus energized._x000D_
Minimum switching current 3 MA at 24 V DC for configurable relay logic._x000D_
Maximum switching current - 5 A at 250 V AC on resistive load - cos phi = 1 - L/R = 0 ms (FL, R,) 5 A at 30 V DC on resistive load - cos phi = 1 - L/R = 0 ms (FL, R), 2 A at 250 V AC on inductive load - cos phi = 0.4 - L/R = 7 ms (FL, R), 2 A at 30 V DC on inductive load - cos phi = 0.4 - L/R = 7 ms (FL, R)._x000D_
Width – 240 mm, Height – 550 mm, Depth – 244 mm._x000D_
Power dissipation 976 W._x000D_
Specific application HVAC (HVAC Compressor, HVAC Fan, HVAC Pump)._x000D_
IP21 Protection._x000D_
Vibration resistance - 1.5 mm (f= 3…13 Hz) conforming to EN/IEC 60068-2-6, 1 gn (f= 13…200 Hz) conforming to EN/IEC 60068-2-8_x000D_
Shock resistance - 15 gn for 11 ms conforming to IEC 60068-2-27._x000D_
Protection Type._x000D_
Overheating protection: drive._x000D_
Thermal power stage: drive._x000D_
Short-circuit between motor phases: drive._x000D_
Input phase breaks: drive._x000D_
Overcurrent between output phases and earth: drive._x000D_
Over-voltages on the DC bus: drive._x000D_
Break on the control circuit: drive._x000D_
Against exceeding limit speed: drive._x000D_
Line supply overvoltage and under-voltage: drive._x000D_
Line supply under-voltage: drive._x000D_
Against input phase loss: drive._x000D_
Thermal protection: motor._x000D_
Motor phase break: motor._x000D_
With PTC probes: motor._x000D_
Standards._x000D_
IEC 61800-3 environments 2 category C1, IEC 61800-3 environments 1 category C3, IEC 61800-3 category C3, IEC 61800-3 category C2, EN 61800-3, IEC 61800-3 environments 1 category C1, IEC 61800-5-1, EN 61800-3 environments 1 category, C1 EN 61800-3 category C3, IEC 61800-3 environments 2 category C2, EN 61800-3 category C2, EN 61800-3 environments 2 category C1, IEC 61800-3, EN 61800-3 environments 1 category C3, UL Type 1, IEC 61800-3 environments 2 category C3, IEC 61800-3 environments 1 category C2, EN 55011 class A group 1, EN 61800-5-1, EN 61800-3 environments 1 category C2, EN 61800-3 environments 2 category C3, EN 61800-3 environments 2 category C2.