The Phoenix Contact's contact extension device is specifically designed for use in conjunction with electrosensitive protective equipment such as light grids. These systems generally have clocked OSSD signals which enable cross circuits in the cabling to be detected. The relay is resistant to the test pulses generated by the electrosensitive protective equipment receiver._x000D_
Mechanical service life approx. 107 cycles_x000D_
nominal input voltage UN 24 V DC_x000D_
Typical input current at UN 70 mA DC_x000D_
Voltage at input/start and feedback circuit 24 V DC_x000D_
Typical response time 25 ms_x000D_
Typical release time 10 ms_x000D_
Concurrence ∞_x000D_
Recovery time 1 s