Работаем с юридическими лицами, бюджетными организациями, ИП
По вопросам приобретения товара пишите на info@west-cs.ru
Dual Position Stainless Steel Float Switch_x000D_
Designed to give the user a number of switching options to cater for a variety of system requirements. These switches are most suited for use with aggressive liquids and hygienic applications._x000D_
Two Independent Switching Points_x000D_
Lower Float Make on Fall, and Upper Float Make on Rise_x000D_
Minimum Fluid SG: 0.80_x000D_
Switch Differential (each level) Nominal: 1mm_x000D_
Suitable for High and Low Level Alarm and Control Signal_x000D_
Stainless Steel 316L for Use with Aggressive Liquids, or in Hygienic Applications_x000D_
Vertical Mounting, M16 x 2 Thread_x000D_
Temperature Range: -20 to +135°C_x000D_
Nitrile Gasket_x000D_
Safe Area for Use in Petrochemical, Storage, and Process Control Applications_x000D_
Note_x000D_
All ratings in tech. spec. table are for resistive loads only_x000D_
Warning_x000D_
The Cable entry point must NOT under any circumstances be submerged._x000D_
On the Horizontal switches they must be fitted through the wall of a tank so that the cable is on the outside._x000D_
On the vertical type the mounting thread and cable entry must be above the highest level of the liquid._x000D_
Sensata Cynergy3 Float Switch, 10 Bar Maximum Operating Pressure, 227mm Length - SSF67 Series - SSF67A25B200_x000D_
Control the level of fluid in your application with this float switch from Sensata Cynergy3. Its mounted vertically inside your tank from the top or bottom, so it's a good option when side access is inconvenient. Thanks to its 316-grade stainless steel body, it's durable and corrosion-resistant for use in demanding environments. When connected to an alarm or control system, it alerts you when liquid rises or falls outside a pre-set range, helping to prevent underfilling and overfilling._x000D_
Features & Benefits_x000D_
Maximum pressure of 10 bar for use in heavy-duty applications_x000D_
Cable length of 1m for an easy connection to the control circuit_x000D_
Nitrile gasket is resistant to chemicals and moisture for a leakproof seal_x000D_
EFTE cable sheath for effective insulation and resistance to chemicals_x000D_
Maximum switching voltage of 250V AC and 120V DC for use in low-power systems_x000D_
How do I install this unit?_x000D_
This float switch is designed for mounting on the inside of your tank. When installing it, ensure that the M16 thread and cable entry are placed above the highest level of the liquid.
Наш менеджер свяжется с вами в ближайшее время